2I17 Noyes M600 OTDR & Fujikura FSM-50S Fusion Splicer |
|
|
|
| |
 |
 |
 |
|
|
|
 |
 |
Noyes M600-K-QUAD-xx-yy Singlemode 1310nm/1550nm & Multimode 850nm/1300nm OTDR
&
Fujikura AFL FSM-50S SM And MM Core Alignment Fusion Splicer With A Fujikura CT-20
Price: $ 13,995.00 / Each
|
 |
|
|
|
| |
 |
 |
 |
|
 |
Noyes M600-K-QUAD-xx-yy OTDR
The M600 is a rugged, field-portable, and very user friendly mini-OTDR. When equipped with multimode and singlemode modules, it is the ideal OTDR for technicians and contractors who test and fault-locate premises, access, metro, and broad-band fiber networks. The M600 offers automatic and manual setup modes to meet the needs of both novice and experienced users.
The M600 OTDR or "optical time domain reflectometer" tests an optical fiber link, while having access to only one end of the link, by generating short pulses of light, sampling reflected light as a function of time, and converting these samples into a graph or "trace" of insertion loss versus distance. Based on the shape of the trace the M600 can locate and analyze fiber link "events" such as connections, splices, bends, and breaks.
Traces can be saved to internal non-volatile memory, CompactFlash™ (removable mass storage device) capable of storing over 1500 traces, or floppy disks. Using the supplied CompactFlash™ reader (USB) or floppy disk, saved traces can be transferred to a PC for archiving, printing, and analyzing with the supplied Trace600 Windows™ software.
The Trace600 batch printing feature is an efficient way to generate hard copy documentation for certification.
Each saved trace is identified using an eight character file name and an optional 30 character cable identifier. To speed up the fiber identification process, the M600 can automatically increment and include a fiber number in each file name. Text may be entered by using the supplied keyboard or by selecting the appropriate letters and numbers from a menu on the M600 display.
The M600 is a full-featured mini-OTDR designed to accept both multimode (850/1300nm) and single-mode (1310/1550nm) modules for testing flexibility. Modules are user installable. All M600 models include: a 7.7-inch color LCD display, CompactFlash™ drive and memory card capable of storing up to 1,500 traces, 3.5-inch floppy disk drive, full-sized keyboard, and soft carry case. Pulse width and range can be set automatically for maximum ease-of-use, or manually for maximum flexibility.
The Trace600 batch-printing feature is an efficient way to generate hard copy documentation for certification. Each saved trace is identified using an eight character file name and an optional 30 character cable identifier. To speed up the fiber identification process, the M600 can automatically increment and include a fiber number in each file name. Text may be entered by using the supplied keyboard or by selecting the appropriate letters and numbers from a menu on the M600 display.
Features:
- Available multimode (850/1300 nm), single-mode (1310/1550 nm), or four-wavelength configurations
- Automatic or manual set up
- Real-time testing
- Large, backlit, color display
- Keyboard with full-sized keys for fast text entry
- Trace storage:
- - CompactFlash™ card (> 1500 traces)
- - 3.5" diskettes (50 traces)
- - internal memory (> 350 traces)
- Trace600 Software for Windows
- Available Fiber Boxes (launch and receive cables)
Specifications:
| Center Wavelengths |
850 /1300 (nm) |
1310/1550 (nm) |
| Testing Applications |
Multimode |
Single-mode |
| Dynamic Range |
21 / 23 dB |
26 / 26 dB |
| Emitter Type |
Laser |
| Emitter Classification |
Class I (FDA 21 CFR 1040.10 & 1040.11) |
| Display Resolution |
0.1 m |
| Event Dead Zone |
< 5 m |
| Attenuation Dead Zone |
< 15 m |
| Index of Refraction |
1.400 - 1.699 |
| Display |
High resolution color, 7.4 adjustable contrast |
| Distance Display Units |
m, km, ft, mi |
| Power |
Lead acid rechargeable battery or AC |
| File Transfer to PC |
3.5 in. floppy disk, CompactFlash reader (USB) |
| Trace Storage |
> 1500 CompactFlash ; > 350 internal; 50 per floppy disk |
| Operating Temp. |
0° to + 40° C |
| Storage Temp. |
-10° to + 60° C |
| Relative Humidity |
0 to 95% non-condensing |
| Weight in Use |
<10 lb (<4.5 kg) |
| Size (H x W x D) |
10.5 x 10.75 x 4.5 in. ( 26.6 x 27.3 x 11.4 cm) |
Fujikura FSM-50S
A number of improvements have been added to the performance-proven Profile Alignment System (PAS) platform, resulting in the smallest and lightest package of its kind. With improved splice & tube-heat time, the splicing operation is the world's fastest truly optimized for field use. Other valuable features include an ergonomic design, reduced numbers of operating steps and a powerful battery extend the boundaries of traditional field fusion splicing performance. The movable monitor and dual-direction operating system essentially gives the operator a choice of two splicers. With these features, the FSM-50S is now more than a tool, it is a work of art.
Features
- Fully automatic core alignment with 9 second splice time for SM fiber
- Reduced splice protector shrink time – now only 35 seconds
- Extremely compact and lightweight – just 2.8kg
- Automatic fibre type identification
- Multi-position monitor for front or top mounting
- High capacity battery option for 120 splice/shrink cycles
- Real time arc calibration
- Fibre clamps integrated into wind protector to reduce operation time
Dual-directional operating system
The reversible monitor accommodates the user's ergonomic preference. With a control panel on each side, the ease of use is phenomenal.
Splice time of 9 sec.
Improved computer processing and newly introduced stepping motor help achieve 9 sec. splice time with SM fiber.
Tube-heat time of 35 sec.
Advanced heater design shortens tube-heat time to 35 sec. with FP-03 protection sleeve.
Large capacity battery option
Two types of slot-in batteries BTR-06S and BTR-06L are available.
Arc calibration-free system
Time-consuming arc calibration is no longer requried with real- time arc calibration.
| Applicable fibers |
SM(ITU-T G.652), MM(ITU-T G.651), DS(ITU -T G.653), NZDS(ITU-T G.655) |
| Fiber Count |
Single |
| Cladding diameter |
80 to 150µm |
| Coating diameter |
100 to 1000µm |
| Fiber cleaved length |
8 to 16mm with coating diameter of 250µm or less. 16mm with coating diameter of 250 to 1000µm.
Optional set-plate for 8 to 16mm with coating diameter of 250 to 1000µm is available. |
| Actual average splice loss |
0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS.
Measured by cut-back method relevant to ITU-T and IEC standards. |
| Splice time |
Typical 9sec. with standard SM fiber. |
| Return loss |
>>60dB |
| Splicing modes |
40 user programmable modes and up to 60 modes for reference(factory predetermined setting). |
| Splice loss estimate |
Available |
| Attenuation splice function |
Intentional high splice loss of 0.1dB to 15dB(0.1dB step) can be made for an in-line fixed attenuator. |
| Storage of splice result |
The last 2000 results to be stored in the internal memory. |
| Fiber display |
X / Y, or both X and Y simultaneously. |
| Magnification |
295x for single X or Y view, or 147x for X and Y view. |
| Viewing method |
Two CMOS cameras and 5.6 inch color LCD monitor. |
| Operating condition |
0 to 5000m above sea level, 0 to 95%RH and -10 to 50? respectively. |
| Mechanical proof test |
2N(standard)/ 4.4N(option) |
| Tube heater |
Built - in tube heater with 10 heating modes and up to 20 modes for reference. |
| Tube heat time |
Typical 35sec. with FP-03 protection sleeve. |
| Applicable protection sleeve length |
60mm, 40mm and a series of micro sleeves. |
| No.of splice/heating with battery |
Typical 80 cycles with BTR-06(S)/ Typical 160 cycles with BTR-06(L). |
| Power supply |
Auto voltage selection from 100 to 240Va.c. or 10 to 15Vd.c. with ADC-11. 13.2Vd.c. with BTR-06(S / L). |
| Terminals |
USB 1.1(USB-B type)for PC communication. Video terminal RCA video jack / NTSC. |
| Wind protection |
Max. wind velocity of 15m/s. |
| Dimensions |
150W × 150D × 150H(mm) |
| Weight |
2.3kg(2.8kg including AC adapter ADC-11) |
Includes:
- Noyes M600-K-QUAD-xx-yy OTDR
- - Singlemode 1310nm & 1550nm
- - Multimode 850nm &1300nm
- Fiber Cables:
- - SM ST-ST
- - SM ST-SC
- - MM ST-ST
- - MM ST-SC
- Noyes Trace 600 OTDR Test Managment Software
- Battery Pack
- AC Adapter/Charger
- Power Cord
- Keyboard
- User Manual On CD-ROM
- Soft Carrying Case
- Fujikura FSM-50S
- Fujikura CT-20 Fiber Cleaver
- (55) Fujikura FP-03 Fiber Splice Protection Sleeves
- Fujikra ACD-11 AC Adapter/Battery Charger
- Fujikura BTR-06 Battery Pack
- Fujikura FH-50-900 Fiber Holder for Cleaver
- Fujikura FH-50-250 Fiber Holder for Cleaver
- AC Adapter/Charger
- Power Cord
- DC Charger Cord
- Spare Electrode Set
- Plastic Screen Cover
- USB PC Interface Cable
- User Manual On CD-ROM
- Hard Carrying Case
|