Agilent E6000A Mini OTDR Mainframe

The Agilent Mini-OTDR is the best selling product in Agilent's portfolio of Optical Network Test Solutions for the installation, maintenance and operation of fiber networks.

The Mini-OTDR is designed to provide its users with the fastest tool available for installing and commissioning multiple fiber links and locating faults for fiber maintenance. This is accomplished through high measurement performance and an award winning simple user interface.

Features
- High dynamic range: 40 dB
- Automatic fiber characterization
- Built-in multi-fiber test
- Fiber break locator mode
- Full remote control
- Simple one-button operation
- Context-sensitive on-line help
- Automatic event adjustment
- Front connector check
- Compliant to Bellcore GR-196-CORE trace format
- Stabilized continuous wave (CW) light source
- Minimum sampling resolution: 8cm
- 15 seconds power up cycle
- Small and light

Characteristics

Horizontal Parameters
- Start-km:
- 0 km to 400 km Span: 0.1 km to 400 km
- Readout resolution: 0.1 m
- Minimum sample spacing: 4 cm
- Refractive index: 1.00000 to 2.00000
- Length unit: km, ft, or miles
- Measurement points: up to 64000

Vertical Parameters
- Vertical scale:
- 0.1 to 10.0 dB/Div Read-out resolution: 0.001 dB
- Reflectance range: 14 dB to 60 dB
- Backscatter coefficient: 10 to 70 dB at 1 s

Storage
- 3.5 floppy disk drive:
- for high density 720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5C to 45C, with 35% to 80% humidity at 40C. Memory Card: PCMCIA Type II. 440 MB with up to 13000 traces (typical with 64000 data points).
- Internal memory: SRAM up to 2 MB. Up to 300 traces (typical) with 4000 data points

Interfaces

RS232C:
- Maximum transmission rate:
- 115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
- Centronics: Standard parallel port (SPP).
- Keyboard: PS2 (Min-DIN). For English Standard, PS2, or AT keyboard.

General
- Automatic setup analysis
- Instrument settings: storage and recall of user-selectable instrument settings.
- Laser safety class: All OTDR laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001).

Built-in Applications
- Automatic Multi Fiber Test
- Pass/Fail Test
- Fiber Break Locator
- Power Meter / Loss Test mode 1
- Visual Fault Finder mode 1
- Optical Return Loss
- End to End Loss
- Easy OTDR
- OTDR Training
- OTDR Assistant

Environmental
- Operating Temperature:
- 0 to 50 degees C Storage Temperature: 40 to +60 degrees C
- Humidity: 95% R.H from 0 to 40 degrees C

Power
- AC: 100 240 Vrms
- 10% 50 60 Hz DC: 16 24 V
- External Battery: NiMHtypically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
- Low battery indicator
- Battery charge status

E6003A Specifications

Central Wavelength 1310 nm ± 25 nm/1550 nm ± 25 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns 1 μs 10 μs 20 μs
Dynamic Range[dB] 21/20 27/25 33/32 40/39 43/41
Event Deadzone 1.5 m
Attenuation Deadzone 8/10 m

E6005A Specifications

Central Wavelength 850 nm ± 30 nm/1300 nm ± 30 nm
Applicable Fiber multimode 62.5 μm
Pulsewidth 10 ns 100 ns 1 μs 10 μs
Dynamic Range[dB] 19/17 26/22 - /28 - /34
Event Deadzone 3 m
Attenuation Deadzone 10 m

E6006A Specifications
Uncertainty at reference conditions: ± 3%
Power level: –20 dBm
Continuous Wave (CW)
Wavelength: 1300 nm ± 3 nm, 1310 nm ± 3 nm, 1550 nm ± 3 nm
Fiber type: 50/125 μm graded index, Agilent/HMS-10 connector
Spectral bandwidth: up to 10 nm
Ambient temperature: +18°C to + 28°C
Total uncertainty: ± 5% ± 0.5 nW (1310, 1550 nm)
Power level: +0 to –50 dBm
Continuous Wave (CW)
Wavelength: 850 nm ± 3 nm, 1300 nm ± 3 nm, 1310 nm ± 3 nm, 1550 nm ± 3 nm,
Fiber type: SM to 50 μm graded index (add 2% to total uncertainty for fiber 62.5 μm).
Ambient temperature: +10°C to +40°C

Includes
- Agilent / HP E6000A Mainframe
- Agilent / HP E6003A Module Singlemode
-- 1310nm
-- 1550nm
- Agilent / HP E6005 Module Multimode
-- 850nm
-- 1300nm
- Agilent / HP E6006A Submodule Power Meter
-- 580nm
-- 1300nm
-- 1310nm
-- 1550nm
-- 1625 nm
- Fiber Cables
-- (2) SM SC-ST
-- MM ST-ST
-- MM SC-ST
- Battery Pack
- AC Adapter/Charger
- Power Cord
- RS-232 PC Interface Cable