2C02 Fluke 725 Multifunction Process Calibrator |
|
|
|
| |
 |
 |
 |
|
|
|
 |
 |
Fluke 725 Multifunction Process Calibrator This Unit Is In Like New
Condition With Protective Film Still On The Screen! Measure volts, mA, RTDs,
thermocouples, frequency, and ohms to test sensors and transmitters
Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and
pressure to calibrate transmitters Measure/source pressure using any of 29
Fluke 700Pxx Pressure Modules Perform fast linearity tests with auto- step
and auto-ramp features
| Regular Price: | $ 1,795.00 / Each |  | | Sale Price: | $ 1,595.00 / Each | | You Save: | $ 200.00 / Each |
|
 |
|
|
|
| |
 |
 |
 |
|
 |
Take along the new Fluke 725 Multifunction Process Calibrator, and you're
equipped to test and calibrate almost any process parameter. Measure and source
mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure,
using optional pressure modules. Do you need to calibrate transmitters? The
725's split display lets you view input and output values simultaneously. For
valve and I/P tests, you can source mA while measuring pressure. The 725 has
auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast
linearity tests. From the moment you pick it up, the Fluke 725 is ready to
perform. Its simple controls, without menus, make operation easy. Its memory
functions make set up fast. And its rugged design lets it work as hard as you
do.
The Fluke 725 Multifunction Process Calibrator is a powerful, yet easy-to-use
field calibrator. Use the measure and source functions to test and calibrate
almost any process parameter.
- Small, streamlined shape makes it easy to carry
- Rugged, reliable design stands up to field use
- Easy to read measure/source screen lets you view input and output
simultaneously
- Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test
sensors and transmitters
- Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and
pressure to calibrate transmitters
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to conduct valve and I/P
tests
- Support flow meter testing with frequency and CPM functions
- Perform fast linearity tests with auto- step and auto-ramp features
- Power transmitters during test using loop supply with simultaneous mA
measurement
- Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as
10 ms
- Store frequently used test setups for later use
- Backlight lets you work in poor light
- Large battery capacity of four AA cells
- Battery door for easy changes
Specifications:
| Measurement
Accuracy |
| Voltage DC |
| 30.000 V |
0.02%+ 2 counts (upper display) |
| 30.000 V |
0.02%+ 2 counts (lower display) |
| 100.00 mV |
0.02%+ 2 counts |
| -10.00 mV to 75.00 mV |
0.025 % + 1 count (via TC
connector) | |
| Current DC |
| 24.000 mA |
0.02%+ 2
counts | |
| Resistance |
| 0.0 to 400.0 O |
0.1O (4-wire), 0.15O (2- and
3-wire) |
| 401 to 1500 O |
0.5O (4-wire), 1O (2- and
3-wire) |
| 1500 to 3200 O |
1O (4-wire), 1.5O (2- and
3-wire) | |
| Frequency |
| 2.0 to 1000.0 CPM |
0.05 % + 1 count |
| 1.0 to 1100.0 Hz |
0.05 % + 1 count |
| 1.00 to 10.00 kHz |
0.05 % + 1 count |
| Sensitivity |
1 V
peak-to-peak-minimum | |
| Pressure |
| Accuracy |
from 0.025% of range using any of 29
pressure modules. |
|
(for detailed specifications refer to
pressure modules in options and accessories) |
|
Modules available for differential,
gage, vacuum, absolute, dual and high
pressure. | |
| Source Accuracy |
| Voltage DC |
| 100.00 mV |
0.02%+2 counts |
| 10.000 V |
0.02%+2 counts |
| -10.00 mV to 75.00 mV |
0.025 % + 1 count (via TC
connector) | |
| Current DC |
| 24.000 mA (Source) |
0.02%+ 2 counts |
| 24.000 mA (Simulate) |
0.02%+ 2
counts | |
| Resistance |
| 15.0 to 400.0 O |
0.15 O (exc. current 0.15 to 0.5 mA),
0.1 O (exc. current 0.5 to 2 mA) |
| 401 to 1500 O |
0.5 O(excitation current 0.05 to 0.8
mA) |
| 1500 to 3200 O |
1 O(excitation current 0.05 to 0.4
mA) | |
| Frequency |
| 2.0 to 1000.0 CPM |
0.05% |
| 1.0 to 1100.0 Hz |
0.05% |
| 1.00 to 10.00 kHz |
0.25% |
| Waveform: |
5 V p-p squarewave, -0.1 V
offset | |
| RTDs and
Thermocouples |
| Measure Accuracy: |
| NI-120 |
0.2 °C |
| PT-100 (385) |
0.33 °C |
| PT-100 (393) |
0.3 °C |
| PT-100 (JIS) |
0.3 °C |
| PT-200 (385) |
0.2 °C |
| PT-500 (385) |
0.3 °C |
| PT-1000 (385) |
0.2 °C |
| Resolution: |
0.1 °C |
| J: |
0.7 °C |
| K: |
0.8 °C |
| T: |
0.8 °C |
| E: |
0.7 °C |
| R: |
1.8 °C |
| S: |
1.5 °C |
| B: |
1.4 °C |
| L: |
0.7 °C |
| U: |
0.75 °C |
| N: |
0.9 °C |
| Resolution |
J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B,
R, S: 1 °C, 1 °F |
| XK |
0.6°C |
| BP |
1.2°C | |
| Source Accuracy: |
| NI-120 |
0.2 °C |
| PT-100 (385) |
0.33 °C |
| PT-100 (393) |
0.3 °C |
| PT-100 (JIS) |
0.3 °C |
| PT-200 (385) |
0.2 °C |
| PT-500 (385) |
0.3 °C |
| PT-1000 (385) |
0.2 °C |
| Resolution: |
0.1 °C |
| Note: |
Accuracy stated for 4-wire
measurement. |
| J: |
0.7 °C |
| K: |
0.8 °C |
| T: |
0.8 °C |
| E: |
0.7 °C |
| R: |
1.4 °C |
| S: |
1.5 °C |
| B: |
1.4 °C |
| L: |
0.7 °C |
| U: |
0.75 °C |
| N: |
0.9 °C |
| Resolution |
J, K, T, E, L, N, U: 0.1 °C, B, R, S:
1 °C |
| XK |
0.6°C |
| BP |
1.2°C | |
| Specifications |
| Ramp Functions |
| Source functions: |
Voltage, current, resistance,
frequency, temperature |
| Ramps |
Slow ramp, Fast ramp, 25%
step-ramp | |
| Loop Power Function |
| Voltage: |
24 V |
| Accuracy: |
10% |
| Maximum current: |
22 mA, short circuit
protected | |
| Step Functions |
| Source functions: |
Voltage, current, resistance,
frequency, temperature |
| Steps |
25% of range, 100% of
range | |
| Environmental
Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Operating Altitude |
|
| Safety
Specifications |
| Agency Approvals |
|
EN 61010-1:1993, ANSI/ISA S82.01-1994;
CAN/CSA C22.2 No 1010.1:1992 | |
| Mechanical & General
Specifications |
| Size |
|
| Weight |
|
| Batteries |
|
| Battery Replacement |
|
Separate battery compartment,
accessable without breaking calibration
seal | |
| Side port connections |
|
Pressure module connector, also used
for remote real-time
programming | |
Includes:
- Fluke 725 Multifunction Process Calibrator
- Fluke TL75 Hard Point Test Lead Set (1 Red - 1
Black)
- Fluke AC20 Alligator Clips
- Hard Copy User Manual
- Original Factory Box
|