PQ01 Fluke 43 HandHeld Power Quality Analyzer Meter |
|
|
|
| |
 |
 |
 |
|
|
|
 |
 |
Fluke 43B single phase power quality analyzer 43b/003 43/003 Includes: Fluke 80i-500s AC Current Probe
Price: $ 1,695.00 / Each
|
 |
|
|
|
| |
 |
 |
 |
|
 |
The Fluke 43 is a single phase power quality analyzer which combines the most useful capabilities of a power quality analyzer, multimeter and scope. It measures power harmonics, captures voltage sags, transients and inrush current. The Fluke 43's monitoring functions help track intermittent problems and power system performance.
The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures.
Features include:
- New! NiMH Battery provides extended operating time of 6.5 hours
- Combines the most useful capabilities of a power quality analyzer, multimeter and scope
- Simulates 3-phase power (assuming balanced loads) from a single-phase measurement
- Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
- Monitoring functions help track intermittent problems and power system performance
- Menus use familiar electrical terminology
- New! Toggle through the most commonly used power quality modes with a single keystroke
- Records two selectable parameters for up to 16 days
- New! 20 measurement memories to save/recall screens and data with cursor readings
- FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
- Measures resistance, diode voltage drop, continuity, and capacitance
- Users / applications manual and power quality video to help answer tough questions
- Complete package with voltage probes and 500A current clamp, FlukeView
- Software and optically isolated interface cable
| Technical Data |
| Input Characteristics |
Input impedance: 1 MW, 20 pF
Voltage Rating: 600V rms, CAT III |
| Volt/Amps/Hertz Display |
True-rms voltage (ac+dc)
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: ±(1% +10 counts)
True-rms current (ac + dc)
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(1% +10 counts)
Mains frequency
Ranges: 40.0 to 70.0 Hz
Accuracy: ±(0.5% +2 counts) |
| Power Display |
Watts, VA, VAR
Ranges: 250 W, 2.50 kW, 25.0 kW, 250 kW, 2.50 MW, 250 MW
Accuracy: ±(4% + 4 counts)
Power Factor, PF
Displacement Power Factor, DPF
Range: 0.00 to 0.25 Accuracy: Not specified
Range: 0.25 to 1.0 Accuracy: ±0.04 |
| Harmonics Display |
Voltage
Ranges: 1st to 51st harmonic
Accuracy: ±(3% +2 counts) to ±(15% +5 counts)
Current
Ranges: 1st to 51st harmonic
Accuracy: ±(3% +8 counts) to ±(5% +8 counts)
Power
Ranges: 1st to 51st harmonic
Accuracy: ±(5% +2 counts) to ±(30% +5 counts)
Line frequency
Ranges: 40 Hz to 70 Hz fundamental
Accuracy: ±0.25 Hz
Phase
Ranges: 2nd to 51st harmonic
Accuracy: ±3 º to ±15 º
K-factor
Ranges: 1.0 to 30.0
Accuracy: ±10% |
| Sags and Swells Recording |
Recording times: 4 min to 16 days (selectable)
True-rms voltage:
Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: ±(2% +10 counts)
True-rms current
Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA
Accuracy: ±(2% +10 counts)
|
| Other Recording |
Recording times: 4 min to 16 days (selectable)
Parameters:
Choose up to two from one of the groups below
V/A/Hz: Line voltage, current, frequency
Power: Watts, VA, VAR, PF, DPF, frequency
Harmonics: THD, harmonic voltage, (or current, or power), frequency, % of total, phase
Ohms: Ohms, diode, continuity, capacitance
Temperature: Temperature
Scope: DC voltage, dc current, ac voltage, ac current, frequency, pulse width, phase, duty cycle, peak max, peak min, peak min-max, crest factor |
| Transient Capture |
Minimum pulse width: 40 ns
Voltage threshold settings: 20%, 50%, 100%, 200% above or below normal voltage
Min voltage and max voltage at cursor:
Ranges: 10V, 25V, 50V, 125V, 250V, 500V, 1250V
Accuracy: ±5% of full scale |
| Inrush Capture |
Current ranges: Ranges: 1A, 5A, 10A, 50A, 100A, 500A, 1000A
Inrush times: Ranges: 1s, 5s, 10s, 50s, 100s, 5 min
Cursor readings, Current at cursor
Ranges: 12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA
Accuracy: ±5% of full scale
Time between cursors
Ranges: 4 to 235 pixels (1 pixel = inrush time/250)
Accuracy: ±(0.2% + 2 pixels) |
| Scope Display |
Time ranges: Ranges: 20 ns/div to 60 s/div
Max sampling rate: Ranges: 25 MS/s
Bandwidth:
Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads
Current channel [2]: 15 kHz at inputs, 10 kHz with 80i-500s Probe
Coupling: AC, DC
Vertical sensitivity: Ranges: 5 mV/div to 500V/div
Vertical resolution: 8 bit (256 levels)
Record length: 512 samples per channel
Timebase modes: Normal, roll, single
Pre-trigger: Up to 10 divisions
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor |
| Ohms, Diode,Continuity |
Ohms:
Ranges: 500.0W, 5.000 kW, 50.00 kW, 500.0 kW, 5.000 MW, 30.00 MW
Accuracy: ±(0.6% +5 counts)
Diode voltage: Accuracy: ±(2% +5 counts)
Continuity: Beeper on at < (30W ±€5W)
Max current: 0.5 mA
Capacitance:
Ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
Accuracy: ±(2% +10 counts)
Temperature**
Ranges: -100.0 ºC to 400.0 ºC, -200.0 ºF to 800.0 ºF
Accuracy: ±(0.5% +5 counts) |
| Screen Memories |
10 |
| Optically Isolated RS-232 Interface |
To printer:
Supports HP Laserjet®, Deskjet®, Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter Cable
To PC:
FlukeView® Power Quality Analyzer Software included |
| FlukeView Power Quality Software |
Hardware requirements:
PC or 100% compatible with Windows® 3.1, Windows® 95, or Windows NT® . Enough RAM for Windows operating system. 4 MB hard drive space. Pointing device (mouse) recommended. |
Includes:
- Fluke 43 HandHeld Power Quality Analyzer
- Fluke 80i-500s AC Current Clamp
- Fluke TL24 Flexible Test Leads (1 Red - 1 Black)
- Fluke AC85A Alligator Clip (1 Red - 1 Black)
- Fluke AC20 Industrial Alligator Clip (1 Red - 1 Black)
- Fluke TP1 Flat Blade Test Pins (1 Red - 1 Black)
- Fluke TP4 4mm Test Pins (1 Red - 1 Black)
- Fluke PM9080 Optically Isolated RS232 Cable
- Fluke BB120
- Flukeview Power Quality Analyzer Software SW43W
- AC Adapter/Charger
- User Manual On CD-ROM
- Hard Copy User Manual
- Hard Carrying Case
|