PQ01 Fluke 43B HandHeld Power Quality Analyzer Meter |
|
|
|
| |
 |
 |
 |
|
|
|
 |
 |
Fluke 43 single phase power quality analyzer 43b/003 43/003 Includes
i400s AC Current Clamp, Hard Carrying Case & Complete
Accessories!!
Price: $ 1,795.00 / Each
|
 |
|
|
|
| |
 |
 |
 |
|
 |
The Fluke 43 is a single phase power quality analyzer which combines the most
useful capabilities of a power quality analyzer, multimeter and scope. It
measures power harmonics, captures voltage sags, transients and inrush current.
The Fluke 43's monitoring functions help track intermittent problems and power
system performance.
The Fluke 43 Power Quality Analyzer performs the measurements you need to
maintain power systems, troubleshoot power problems and diagnose equipment
failures.
Features include:
- New! NiMH Battery provides extended operating time of 6.5 hours
- Combines the most useful capabilities of a power quality analyzer,
multimeter and scope
- Simulates 3-phase power (assuming balanced loads) from a single-phase
measurement
- Trends voltage, current, frequency, power harmonics and captures voltage
sags, transients and inrush current
- Monitoring functions help track intermittent problems and power system
performance
- Menus use familiar electrical terminology
- New! Toggle through the most commonly used power quality modes with a
single keystroke
- Records two selectable parameters for up to 16 days
- New! 20 measurement memories to save/recall screens and data with cursor
readings
- FlukeView® software can log harmonics and all other readings over time and
provides a complete harmonics profile up to the 51st harmonic
- Measures resistance, diode voltage drop, continuity, and capacitance
- Users / applications manual and power quality video to help answer tough
questions
- Complete package with voltage probes and 500A current clamp, FlukeView
- Software and optically isolated interface cable
| Technical Data |
| Input Characteristics |
Input impedance: 1 MW, 20 pF Voltage
Rating: 600V rms, CAT III |
| Volt/Amps/Hertz Display |
True-rms voltage (ac+dc) Ranges: 5.000V,
50.00V, 500.0V, 1250V* Accuracy: ±(1% +10 counts) True-rms current
(ac + dc) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy:
±(1% +10 counts) Mains frequency Ranges: 40.0 to 70.0 Hz
Accuracy: ±(0.5% +2 counts) |
| Power Display |
Watts, VA, VAR Ranges: 250 W, 2.50 kW, 25.0
kW, 250 kW, 2.50 MW, 250 MW Accuracy: ±(4% + 4 counts) Power
Factor, PF Displacement Power Factor, DPF Range: 0.00 to 0.25
Accuracy: Not specified Range: 0.25 to 1.0 Accuracy: ±0.04 |
| Harmonics Display |
Voltage Ranges: 1st to 51st harmonic Accuracy:
±(3% +2 counts) to ±(15% +5 counts) Current Ranges: 1st
to 51st harmonic Accuracy: ±(3% +8 counts) to ±(5% +8 counts)
Power Ranges: 1st to 51st harmonic Accuracy: ±(5% +2
counts) to ±(30% +5 counts) Line frequency Ranges: 40 Hz
to 70 Hz fundamental Accuracy: ±0.25 Hz Phase Ranges: 2nd
to 51st harmonic Accuracy: ±3 º to ±15 º K-factor Ranges:
1.0 to 30.0 Accuracy: ±10% |
| Sags and Swells Recording |
Recording times: 4 min to 16 days (selectable)
True-rms voltage: Ranges: 5.000V, 50.00V, 500.0V, 1250V*
Accuracy: ±(2% +10 counts) True-rms current Ranges:
50.00A, 500.0A, 5.000 kA, 50.00 kA Accuracy: ±(2% +10 counts) |
| Other Recording |
Recording times: 4 min to 16 days (selectable)
Parameters: Choose up to two from one of the groups
below V/A/Hz: Line voltage, current, frequency
Power: Watts, VA, VAR, PF, DPF, frequency
Harmonics: THD, harmonic voltage, (or current, or power),
frequency, % of total, phase Ohms: Ohms, diode,
continuity, capacitance Temperature: Temperature
Scope: DC voltage, dc current, ac voltage, ac current,
frequency, pulse width, phase, duty cycle, peak max, peak min, peak
min-max, crest factor |
| Transient Capture |
Minimum pulse width: 40 ns Voltage
threshold settings: 20%, 50%, 100%, 200% above or below normal
voltage Min voltage and max voltage at cursor: Ranges:
10V, 25V, 50V, 125V, 250V, 500V, 1250V Accuracy: ±5% of full scale |
| Inrush Capture |
Current ranges: Ranges: 1A, 5A, 10A, 50A,
100A, 500A, 1000A Inrush times: Ranges: 1s, 5s, 10s, 50s,
100s, 5 min Cursor readings, Current at cursor Ranges:
12.5A, 25A, 50A, 125A, 250A, 500A, 1250A, 2500A, 5 kA Accuracy: ±5% of
full scale Time between cursors Ranges: 4 to 235 pixels
(1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels) |
| Scope Display |
Time ranges: Ranges: 20 ns/div to 60 s/div
Max sampling rate: Ranges: 25 MS/s
Bandwidth: Voltage channel [1]: 20 MHz at inputs, 1 MHz
with TL24 Leads Current channel [2]: 15 kHz at inputs, 10 kHz with
80i-500s Probe Coupling: AC, DC Vertical
sensitivity: Ranges: 5 mV/div to 500V/div Vertical
resolution: 8 bit (256 levels) Record length:
512 samples per channel Timebase modes: Normal, roll,
single Pre-trigger: Up to 10 divisions
Measurements: dc, ac, ac+dc, peak, peak-peak, frequency,
duty cycle, phase, pulse width, crest factor |
| Ohms, Diode,Continuity |
Ohms: Ranges: 500.0W, 5.000 kW, 50.00 kW,
500.0 kW, 5.000 MW, 30.00 MW Accuracy: ±(0.6% +5 counts) Diode
voltage: Accuracy: ±(2% +5 counts) Continuity:
Beeper on at < (30W ±¤5W) Max current: 0.5 mA
Capacitance: Ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00
µF, 500.0 µF Accuracy: ±(2% +10 counts) Temperature**
Ranges: -100.0 ºC to 400.0 ºC, -200.0 ºF to 800.0 ºF Accuracy: ±(0.5% +5
counts) |
| Screen Memories |
10 |
| Optically Isolated RS-232 Interface |
To printer: Supports HP Laserjet®, Deskjet®,
Epson FX/LQ and Postscript printers with optional PAC91 Printer Adapter
Cable To PC: FlukeView® Power Quality Analyzer Software
included |
| FlukeView Power Quality Software |
Hardware requirements: PC or 100% compatible
with Windows® 3.1, Windows® 95, or Windows NT® . Enough RAM for Windows
operating system. 4 MB hard drive space. Pointing device (mouse)
recommended. |
Includes:
- Fluke 43 HandHeld Power Quality Analyzer
- Fluke i400s AC Current Clamp
- Fluke Alligator Clips AL85A (1 Red - 1 Black)
- TL24 Test Lead Set (1 Red - 1 Black)
- Industrial Large Alligator (1 Red - 1 Black)
- Test Pins 2mm TP1 (1 Red - 1 Black)
- Test Pins 4mm TP4 (1 Red - 1 Black)
- Battery Pack
- AC Adapter/Charger
- Power Quality Analyzer Getting Started Guide
- User Manual On CD-ROM
- Hard Carrying Case
|