PQ02 Fluke 433 HandHeld Power Quality Analyzer Meter
Fluke 433 single phase power quality analyzer 433b/003 433/003
Price: $ 3,495.00 / Each
The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use handhelds are a “must have” for any person who maintains or troubleshoots three phase distribution. The new IEC standards for flicker and power quality are built right in to take the guess work out of monitoring.
- Records all your necessary values in a three phase system.
- Minimal setup required with intuitive menus.
- Highest safety rating in the industry.
- Four voltage and four current channels.
- Captures waveform data on all phases simultaneously.
- System-Monitor: Six power quality parameters on one dashboard
- Automatic Transient display: Never miss an event.
- Auto Trend: Don’t waste time setting up recordings.
- Rugged, handheld recorder.
- Seven hours operating time per charge on NiMH battery pack.
- Transfer data files to your PC for reporting and analysis using FlukeView® software.
Input characteristics
Voltage inputs
Number of inputs
4 (3 phases + neutral)
Maximum input voltage
1000 Vrms
Maximum peak voltage
6 kV
Input impedance
4 MW / 5 pF
Band
9 kHz, up to 100 kHz for transient display
Scaling
1:1, 10:1, 100:1, 1000:1 and variable
Current inputs
Number of inputs
4 (3 phases + neutral)
Type
Clamp on current transformer with mV output
Range
1 to 400 Arms with included clamps (I400S) 0.1 to 3000 Arms with optional clamps
Input impedance
50 kW
Band
9 kHz
Scaling
0.1, 1, 10, 100, 1000 mV/A and variable
Nominal frequency
40 to 70 Hz
Sampling system
Resolution
16 bit analog to digital converter on 8 channels
Maximum sampling speed
200 kS/s on each channel simultaneously
RMS sampling
5000 samples on 10/122 cycles according IEC 61000-4-30
PLL synchronization
4096 samples on 10/122 cycles according IEC 61000-4-7
Display modes
Waveform display
Available in Scope and Transient mode Captures 8 waveforms simultaneously Display update rate 5 x per second Up to 10/12 times horizontal zoom2 Cursors: Single vertical line showing min, max, avg reading at cursor position
Phasor
Shows real time phasor diagram Available in Scope and Unbalance mode Display update rate 5 x per second
Matrix readings
Available in Volts/Amps/Hertz, Harmonics, Power & Energy, Flicker and Unbalance mode
AutoTrend graph
Available in Volts/Amps/Hertz, Dips & Swells, Harmonics, Power & Energy, Flicker, Unbalance, Inrush and Monitor mode Cursors: single vertical line showing with min, max, avg reading at cursor position
Bargraph
Available in Harmonics and Monitor mode
Eventlist
Available in Dips & Swells and Monitor mode
Measurement modes
Scope
Vrms, Arms, Vcursor, Acursor, Vfund, Afund, Hz, V phase angles, A phase angles
Volts/Amps/Hertz
Vrms, Vpk, V Crest Factor, Arms, Apk, A Crest Factor, Hz
Dips and Swells
Vrms1.2 , Arms1.2 Captures up to 1000 events with date, time, duration, magnitude and phase identification with programmable thresholds
Harmonics DC, 1 to 50
Harmonic Volts, THD Volt, Harmonic Amps, THD Amps, K Amps, Harmonic Watts, THD Watts, K Watts, Interharmonic Volts4, Interharmonic Amps4 (relative to fundamental or to total rms)
Power and Energy4
Watts, VA, VAR, Power factor, Cos j / DPF, Arms, Vrms, kWh, kVAh, KVARh, peak demand interval using trend, KYZ revenue meter verification via optional input
Vneg, Vzero, Aneg, Azero, Vfund, Afund, Hz, V phase angles, A phase angles
Transients4
Vrms, Arms, Vcursor, Acursor
Inrush Currents4
Inrush Current, Inrush duration, Arms1.2, Vrms1.2
System Monitor
Vrms, Arms, Harmonic Volts, THD Volts, Plt, Vrms1.2 , Arms1.2 , Vneg, Hz, dips and swells, unbalance. All parameters are measured simultaneously in accordance with EN50160. Using Flagging to indicate unreliable readings according IEC61000-4-30.
Accuracy, resolution and range
Volt/Amps/Hertz
Measurement range
Resolution
Accuracy
Vrms (AC+DC)
1 to 1000 Vrms
0.1 Vrms
± 0.5 % of nominal voltage
Vpk
1 to 1400 Vpk
1 V
5 % of nominal voltage
CFV
1.0 to > 2.8
0.1
± 5 %
Arms (AC+DC) with included clamps
0 to 20,000 Arms1 0 to 400 Arms
0,001 to 10 Arms1 0.1 and 1 Arms
± 1 % of reading ± 5 counts3
Apk using 1mV/A scaling
0 - 5500 Apk
10:00 AM
± 5 %
CFA using 1mV/A scaling
1 to 10
0.1
± 5 %
50 Hz nominal
42.50 to 57.50 Hz
0.01 Hz
± 0.1 % of nominal frequency
60 Hz nominal
51.00 to 69.00 Hz
0.01 Hz
± 0.1 % of nominal frequency
Dips and swells
Vrms1.2 (AC+DC)
0.0 to100 % of nominal voltage
0.1Vrms
± 1 % of nominal voltage
Arms1.2 (AC+DC) with included clamps
0 to 20,000 Arms 0 to 400 Arms
0,001 Arms to 10 Arms 0.1 Arms and 1 Arms
± 1 % of reading ± 5 counts3
Threshold levels
Programmable in percent of nominal voltage
Duration
hhh,mm,ss,mmm with half-cycle cycle time resolution
Harmonics
Harmonic selection (n)
DC, 1 to 50
Inter-Harmonic selection
Off, 1 to 49
Vrms Relative (%f): Absolute:
0.0 to 100.0 % 0.0 to 1000 Vrms
0.1 % 0.1 Vrms
± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 2 counts
Arms Relative (%f): Absolute:
0.0 to 100.0 % 0.0 to 4000 mV x selected clamp scaling
0.1 % 1 mVrms x selected clamp scaling
± 0.1 % ± n x 0.1 % (± 0.4 % for %r) ± 5 % of reading ± 5 counts
Watts Relative: Absolute:
0.0 to 100.0 % depends on selected clamp and voltage scaling
0.10%
± n x 2 % ± 5 % of reading ± n x 2 % of reading, ± 10 counts
DC voltage Relative: Absolute:
0.0 to 100.0 % 0.0 to 1000 V
0.1 % 0.1 V
± 1 % ± 5 % of reading ± 10 counts
THD
0.0 to 100.0 %
0.10%
± 2.5 %
Hz
0 to 3500 Hz
1 Hz
± 1Hz
Phase angle
-360 o to +360 o
1 o
± n x 1.5 o
Power and Energy
Watt
1.0 W to 20.00 MW1
0.1 W to 1 kW1
± 1.5 % of reading ± 10 counts3
VA
1.0 VA to 20.00 MVA1
0.1 VA to 1 kVA1
± 1.5 % of reading ± 10 counts3
VAR
1.0 VAR to 20.00 MVAR1
0.1 VAR to 1 kVAR1
± 1.5 % of reading ± 10 counts3
kWh
00.00 kWhr to 200.0 GWhr1
0.01 Whr to 100 Whr1
± 1.5 % of reading ± 10 counts3
kVA
00.00 kVAhr to 200.0 GVAhr1
0.01 VAhr to 100 VAhr1
± 1.5 % of reading ± 10 counts3
kVAR
00.00 kVARhr to 200.0 GVARhr1
0.01 VARhr to 100 VARhr1
± 1.5 % of reading ± 10 counts3
Power Factor
0 to 1
0.01
± 0.033
Cos j / DPF
0 to 1
0.01
± 0.033
Flicker
Pst (1min), Pst, Plt, PF5 instantenous Flicker
0.00 to 20.00
0.01
Within ± 5 % of tabulated values according IEC61000-4-15
Dc %, Dmax % and Time d(t) exceeds limits. As described per IEC 61000-3-3
0.0 to ± 100.0 % for Dc % and Dmax % and 0.000 to 9.999s for Time
0.1 % for Dc % and Dmax % and 10 ms for Time
± 1% for Dc % and Dmax % and 20 ms for Time
Unbalance
Volts
0.0 to 5.0 %
0.10%
± 0.5 %
Current
0.0 to 20 %
0.10%
± 1 %
Transient capture
Volts
± 6000 Vpk
1 V
± 15 % of cursor reading ± 2.5 % of Vrms
Minimum detect duration
5 ƒÊs
Sampling rate
200 kS/s
Inrush mode
Arms (AC+DC)
0.000 to 20.00 kArms1
0.001 to 10 Arms1
± 1 % of meas ± 5 counts3
Inrush Duration
mm:ss:mmm between 7.5 s to 30 m selectable
10 ms
± 20 ms (Fnominal = 50 Hz)
Includes:
- Fluke 433 Power Quality Analyzer
- (4) Fluke i400S AC Current Clamps
- Fluke TLS430
--- (5) Test Leads (4 Black - 1 Green)
--- (5) Alligator Clips (4 Black - 1 Green)
- AC Adapter/Charger
- Power Cord
- Carrying Strap
- ScopeMeter Accessory Guide
- Getting Started Guide
- User Manual On CD-ROM
- Hard Carrying Case With Keys