The microprocessor controlled fusion splicer is used for mechanically durable, low-loss fusing of optical fibers with long-term stability.
Fiber Diameters Single-mode fibers, dispersion-shifted single-mode fibers and multimode fibers with coating diameters of up to 900 um can be fused. The splicer is designed for use with the standard 125 um outside fiber diameter (without coating). If you need to splice fibers with other diameters, please contact the manufacturer.
Automatic Fiber Positioning Fiber positioning and the fusion process run automatically. This assures uniform high quality results independent of the operator. Two mutually independent processes for positioning and automatic splice loss determination have been integrated into the splicer. The time tested LID system (Local Injection and Detection) allows for accurate core-to-core positioning of the fiber ends such that good splicing results can even be achieved with singlemode fibers with eccentric cores. It also allows for the measurement of splice loss at an operational wavelength of 1300 nm. If the LID system cannot be used (e.g. with tight-buffered fibers), the completed splice is analyzed with the L-PAS -video system (Lens Profile Alignment System), and splice loss is indicated in dB as well.
Fiber Requirements: Single and multimode glass fiber with 125 um glass diameter, 250 to 900 um coating diameters Fiber Display: High contrast 5.5" color LCD Magnification: Approximately 100 power Fiber Positioning: Fully automatic in X, Y and Z axes Mean Splice Loss for Identical, Standard Single-Mode Fibers: * Multimode fiber: typ. < 0.01 dB * Standard single-mode fiber: typ. < 0.02 dB Tensile Test: Automatic / OFF Splicing Programs: Preset, special and user programs Video Output: CCIR output (75 ohm) Mains Power: 95 to 260 V with automatic voltage range selection, 50 - 60 Hz, max 100 VA External 12 V Power Supply: 12 - 14.5 V, max. 5 A, pole reversal protected Data Memory Capacity: 1000 splice values Data Output: RS 232 interface with adjustable baud rate LID System: Wavelength: 1300 nm, temperature compensated Attenuation Splices: 1 to 10 dB (in steps of 0.1 dB) Real-Time Clock: Time and date display with battery backup Operating Temperature: -5° C to +45° C Storage Temperature: -20° C to +70° C
INCLUDES: - Siecor M90 3000 Series Fusion Splicer SM MM V6.2.2 - Siecor FCB-005 Attached Fiber Cleaver - Siecor 125/250 Micron Fiber Holder Set - Siecor 125/900 Micron Fiber Holder Set - RXS S4699-M7-S343 Attached Heat Shrink Oven - Assorted Tool Kit - Overhead Lamp - Power Cord - User Manual On CD-ROM - Integrated Hard Case